Why does the write command to EPCQ512A quad serial configuration devices fail when using Arria® V, Cyclone® V or Stratix® V devices ? - Why does the write command to EPCQ512A quad serial configuration devices fail when using Arria® V, Cyclone® V or Stratix® V devices ?
Description Due to a known problem with designs compiled in Intel Quartus® Prime software 16.1 update 1 or earlier, flash writes to EPCQ512A devices may fail when using the ASMI Parallel P or Remote Update IP for EPCQ device configured in QUAD mode, i.e. ASx4 mode. This is because the opcode for EPCQ Extended Quad writes is generated incorrectly. Resolution For designs compiled in Intel Quartus Prime software 16.1 update 1 or earlier, the write opcode needs to be changed to 38h. This problem has been fixed in Intel Quartus Prime Standard version 16.1 update 2 and later.
Custom Fields values:
['novalue']
Troubleshooting
FB: 525767;
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Standard']
16.1.2
novalue
['Arria® V FPGAs and SoCs', 'Cyclone® V FPGAs and SoCs', 'Stratix® V FPGAs']
['novalue']
['Configuration Device EPCQ']
['novalue'] - 2021-08-25
external_document