Are there any known problems when trying to simulate the Quartus II software versions 12.1, or 12.1sp1 10GBASE-KR PHY IP in Cadence ncsim? - Are there any known problems when trying to simulate the Quartus II software versions 12.1, or 12.1sp1 10GBASE-KR PHY IP in Cadence ncsim?
Description Yes, If you try and simulate the Quartus® II software versions 12.1 or 12.1sp1 10GBASE-KR PHY Intel® FPGA IP in Cadence NCSIM, the following errors might be seen: Error: … ncelab: *W,STARMT: This @* expands to empty list, will never wake up. ncelab: *W,STARMT: This @* expands to empty list, will never wake up. ncelab: *E,CUVMOC: illegal mix of varibles and nets in concatenation expression connected to an output port. … Resolution To work around this problem, copy the attached file lt_tx_data.sv to the following directory: xcvr_10gbase_kr_sim/altera_xcvr_10gbase_kr/cadence/ This problem will be fixed in a future version of the 10GBASE-KR PHY Intel FPGA IP.
Custom Fields values:
['novalue']
Troubleshooting
1408015137
False
['novalue']
['FPGA Dev Tools Quartus II Software']
13.0
12.1
['Stratix® V FPGAs', 'Stratix® V GX FPGA']
['novalue']
['novalue']
['novalue'] - 2023-03-23
external_document