Why does the Agilex™ FPGA EMIF simulation log have additional CALBUS messages? - Why does the Agilex™ FPGA EMIF simulation log have additional CALBUS messages?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 22.1, you may see these additional CALBUS messages during the simulation of the Agilex™ FPGA EMIF: .... 4IOSS CALBUS Read -- addr=12107, data=00000000 4IOSS CALBUS Read -- addr=06107, data=00000000 4IOSS CALBUS Read -- addr=12107, data=00000000 4IOSS CALBUS Read -- addr=06107, data=00000000 4IOSS CALBUS Read -- addr=06108, data=00000060 4IOSS CALBUS Read -- addr=06103, data=00000000 4IOSS CALBUS Read -- addr=06107, data=00000000 4IOSS CALBUS Read -- addr=12107, data=00000000 4IOSS CALBUS Read -- addr=12108, data=00000060 .... Resolution To disable those messages, revert to the previous IOSSM as described here: External Memory Interfaces Agilex™ FPGA IP User Guide This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Troubleshooting
14016507864
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
22.2
22.1
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-11-08
external_document