Critical Warning: parameter 'crcchk_init' of instance '...|sv_hssi_10g_rx_pcs_rbc' has illegal value '' assigned to it. Valid parameter values are: '(crcchk_int)'. Using value 'crcchk_int' - Critical Warning: parameter 'crcchk_init' of instance '...|sv_hssi_10g_rx_pcs_rbc' has illegal value '' assigned to it. Valid parameter values are: '(crcchk_int)'. Using value 'crcchk_int' Description You may see the following warning message when implementing the Stratix® V device 10GBaser-R IP in Quartus® II software versions 13.1 and earlier. Info (10648): Verilog HDL Display System Task info at sv_hssi_10g_rx_pcs_rbc.sv(1916): Critical Warning: parameter 'crcchk_init' of instance '...|sv_hssi_10g_rx_pcs_rbc' has illegal value '' assigned to it. Valid parameter values are: '(crcchk_int)'. Using value 'crcchk_int' Info (10648): Verilog HDL Display System Task info at sv_hssi_10g_tx_pcs_rbc.sv(1822): Critical Warning: parameter 'crcgen_init' of instance '...|sv_hssi_10g_tx_pcs_rbc' has illegal value '' assigned to it. Valid parameter values are: '(crcgen_int)'. Using value 'crcgen_int' Resolution This warning can be safely ignored. This warning is scheduled to be removed in a future version of the Quartus II software. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['FPGA Dev Tools Quartus II Software'] novalue 13.1 ['Stratix® V FPGAs', 'Stratix® V GS FPGA', 'Stratix® V GT FPGA', 'Stratix® V GX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25

external_document