In the 10GBASE-R PHY MegaWizard Plug-In Manager, compilation fails for Stratix IV GX if you select a Starting channel number other than the default value 0 - In the 10GBASE-R PHY MegaWizard Plug-In Manager, compilation fails for Stratix IV GX if you select a Starting channel number other than the default value 0
Description In the 10GBASE-R PHY MegaWizard Plug-In Manager, if you select a Starting channel number other than the default value 0 , compilation fails with an error similar to the following: Error: Cannot find Memory initialization File or Hexadecimal (Intel-Format) File <file name> for ROM instance <instance name> Resolution Since every instantiation of the 10GBASE-R PHY megafunction includes a reconfiguration block, 0 is the correct starting channel number. Do not change the value of Starting channel number .
Custom Fields values:
['novalue']
Troubleshooting
novalue
True
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
10.0
['Stratix® IV FPGAs']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document