xmelab: *F,CUMSTS: Timescale directive missing on one or more modules. - xmelab: *F,CUMSTS: Timescale directive missing on one or more modules.
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.1, you may see this error message while simulating the High Bandwidth Memory (HBM2) Interface Intel FPGA IP Design Example with the Cadence* Xcelium* simulator. Resolution To work around this problem in the Intel® Quartus® Prime Pro Edition Software version 21.1, follow the steps below: Go to <example_design_path>/sim/ed_sim/sim/xcelium/ Open xcelium_setup.sh with your preferred text editor Locate 'USER_DEFINED_ELAB_OPTIONS' line and add the '-timescale 1ps/1ps' option . After editing xcelium_setup.sh, the 'USER_DEFINED_ELAB_OPTIONS' line will look as follows: USER_DEFINED_ELAB_OPTIONS="-timescale 1ps/1ps" Execute ./xcelium_setup.sh This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 21.3.