*** Fatal Error: Access Violation at 0X000000000A3B2530 - *** Fatal Error: Access Violation at 0X000000000A3B2530
Description Due to a problem with the Quartus® II software versions 12.1 and earlier, you may see this error when clicking on a Located Entity report from a previous compilaton within the Chip Planner. This error occurs because the Quartus II software fails to delete any Located Entity report within the Chip Planner before starting a new compilation. Resolution To avoid this error, manually delete any Located Entities reports from the Chip Planner before performing a new compilation. This issue is scheduled to be fixed in a future release of the Quartus II software.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
10.0
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document