Should CONF_DONE and INIT_DONE assert high during Stratix® 10 FPGA JIC file programming with the Quartus® Prime Pro Edition Software v18.0? - Should CONF_DONE and INIT_DONE assert high during Stratix® 10 FPGA JIC file programming with the Quartus® Prime Pro Edition Software v18.0? Description No, the CONF_DONE and INIT_DONE signals should not assert high during Stratix® 10 FPGA JIC file programming. When using the Quartus® Prime Pro Edition Software v18.0 to configure an Stratix® 10 FPGA device with the helper image (Factory default SFL image) during the JIC file programming process, you might observe unexpected CONF_DONE and INIT_DONE signal assertions. The helper image (Factory default SFL image) only contains firmware data and not the full configuration data. Thus, the Stratix® 10 FPGA device is only configured with the firmware data, and even though the CONF_DONE and INIT_DONE signals are asserted high, the Stratix® 10 FPGA device has not entered the user mode. In the Quartus® Prime Pro Edition Software v17.1 and earlier, the CONF_DONE and INIT_DONE signals are expected to be asserted high as the helper image (Factory default SFL image) contains full configuration data. Resolution This invalid CONF_DONE and INIT_DONE state will not cause any JIC programming failure. This is fixed in the Quartus® Prime Pro Edition Software v21.4 and above. Custom Fields values: ['novalue'] Troubleshooting 2205968472 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 21.4 18.0 ['Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2024-10-23