Why am I seeing an error “read Ethernet ANLT channel 0 register anlt_ltstat_csr6” or link training failure during hardware testing when using F-tile Dynamic Reconfiguration Suite IP with Auto-negotiation and Link Training (AN/LT) enabled? - Why am I seeing an error “read Ethernet ANLT channel 0 register anlt_ltstat_csr6” or link training failure during hardware testing when using F-tile Dynamic Reconfiguration Suite IP with Auto-negotiation and Link Training (AN/LT) enabled?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 24.3, you may see an error during hardware testing when using the F-Tile Dynamic Reconfiguration Suite IP with Auto-negotiation and Link Training (AN/LT) enabled, and if user logic is enabled. The error may look like below: Resolution For a workaround, follow the steps below: ) Navigate to “../[example design]/hardware_test_design/hwtest/tests/ftile_eth_dr_test.tcl” ) Search for “ Setting sequencer reset ” code a) For FGT designs, comment line #386 as shown below: b) For FHT designs, modify line #386 as shown below: This problem is fixed beginning with the Quartus® Prime Pro Edition software version 24.3.1.
Custom Fields values:
['novalue']
Troubleshooting
14023417934
False
['F-Tile Dynamic Reconfiguration Suite IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
24.3.1
24.3
['Agilex™ 5 FPGAs and SoCs', 'Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2025-06-11
external_document