Error-[PE_CDB] Corrupted data_block. Checksum did not match for data_block in file - Error-[PE_CDB] Corrupted data_block. Checksum did not match for data_block in file Description This error may occur when calling the Quartus® EDA Simulation Library Compiler using a 32-bit version of the Synopsys VCS* simulator in the Quartus® Prime Pro Edition Software version 24.1 and earlier. Resolution Synopsys VCS* compilation must be run with 64-bit support. This error can be fixed with either of the following steps: Add the "-full64" flag to the command line, some Design Examples do this by default. Set the VCS_TARGET_ARCH appropriately, for example to "linux64" or "suse64". Custom Fields values: ['novalue'] Troubleshooting 14021353768 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 23.3 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2024-05-06