Why do I get reconfiguration error with Intel® Cyclone® V, Arria® V, and Stratix® V devices when the POF check option is enabled in the Remote Update IP? - Why do I get reconfiguration error with Intel® Cyclone® V, Arria® V, and Stratix® V devices when the POF check option is enabled in the Remote Update IP?
Description When you instantiate the Remote Update IP with the EPCQ-A device and have the POF Check option enabled, reconfiguration of your Intel® Cyclone® V, Arria® V, and Stratix® V device may fail. Resolution Use EPCS instead of EPCQ-A with the same density when instantiating the Remote Update IP. This problem is fixed starting with the Intel® Quartus® Prime Standard Edition Software version 19.1.”
Custom Fields values:
['novalue']
Troubleshooting
FB: 588419; 2205692756
False
['Remote Update IP']
['FPGA Dev Tools Quartus® Prime Software Standard']
19.1
17.1.2
['Arria® V FPGAs and SoCs', 'Cyclone® V FPGAs and SoCs', 'Stratix® V FPGAs']
['novalue']
['novalue']
['novalue'] - 2023-01-19
external_document