Why is the Intel Agilex® 7 E-Tile transceiver reference clock REFCLK_GXE termination assignment being ignored by the Intel® Quartus® Prime Pro Edition Software version 21.2 and earlier Fitter? - Why is the Intel Agilex® 7 E-Tile transceiver reference clock REFCLK_GXE termination assignment being ignored by the Intel® Quartus® Prime Pro Edition Software version 21.2 and earlier Fitter?
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.2 and earlier, the Quartus Fitter reports that the .qsf assignments for Intel Agilex® 7 E-Tile reference clock termination are ignored. This problem is a reporting error, the termination is correctly applied. Resolution This problem is fixed beginning with the Intel® Quartus® Prime Pro Edition Software version 22.1.
Custom Fields values:
['novalue']
Troubleshooting
14014530032
False
['E-Tile Transceiver Native PHY Agilex™ 7 FPGA IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
22.1
21.2
['Agilex™ 7 FPGA F-Series']
['novalue']
['novalue']
['novalue'] - 2023-12-21
external_document