Why does the Design Space Explorer return unknown values when compiling designs targeting Cyclone II or Stratix II devices? - Why does the Design Space Explorer return unknown values when compiling designs targeting Cyclone II or Stratix II devices?
Description Due to a problem in the Quartus® II software, the Design Space Explorer may return unknown values when compiling designs targeting Stratix® II or Cyclone® II devices. This problem occurs when the Design Space Explorer attempts to use the deprecated Classic Timing Analyzer instead of the TimeQuest timing analyzer. To work around this problem, add the following assignment to your Quartus II Settings File ( .qsf ): set_global_assignment -name USE_TIMEQUEST_TIMING_ANALYZER ON This problem is scheduled to be fixed in a future version of the Quartus II software.
Custom Fields values:
['novalue']
Troubleshooting
novalue
False
['novalue']
['novalue']
novalue
novalue
['Cyclone® II FPGAs', 'Stratix® II FPGAs', 'Stratix® II GX FPGA']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document