Why does my Arria V GZ Nios II design fail to boot up in V13.1 and V14.0 - Why does my Arria V GZ Nios II design fail to boot up in V13.1 and V14.0 Description Due to a problem in the Quartus® II software version 13.1 and version 14.0, Nios® II designs targeting Arria V GZ devices using the EPCS IP may not boot correctly. Resolution To work around this problem follow the steps below: Open /ip/altera/sopc_builder_ip/altera_avalon_epcs_flash_controller/em_epcs_qsys.pm file in a text editor. Remove "( eq "ARRIAVGZ") ||", Arria V GZ device from the condition check logic at line 699. This problem is scheduled to be fixed in a future release of the Quartus® II software. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['FPGA Dev Tools Quartus II Software'] novalue 13.1 ['Arria® V GZ FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25