Why do I observe configuration failure in Intel® Stratix® 10 devices which require a power cycle to recover for the subsequent configuration? - Why do I observe configuration failure in Intel® Stratix® 10 devices which require a power cycle to recover for the subsequent configuration? Description When powering up the Stratix® 10 device, once the configuration process starts where the nCONFIG goes high, if there is an interruption before the CONF_DONE goes high, the configuration process will fail due to the firmware is unable to handle the interruption. As long there is an interruption between the nCONFIG high to CONF_DONE high period, the configuration process will fail. An interruption is classified as one of the following: a. pulsing the nCONFIG b. initiating JTAG configuration c. bitstream corruption You may encounter this issue using Intel® Quartus® Prime Pro Edition Software version 17.1 (including Update 1 and Update 2). This issue impacts all Stratix® 10 configuration schemes. Resolution When the configuration failure occurs, you need to power cycle the Stratix® 10 device for subsequent configuration. This problem is fixed starting with the Intel® Quartus® Prime Pro Edition Software version 18.0. Custom Fields values: ['novalue'] Troubleshooting FB: 480307490604; False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 18.0 17.1 ['Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2022-12-23