Why do I see an error when running the Design Assistant on the HDMI design in Intel® Quartus® Prime Standard Edition Software? - Why do I see an error when running the Design Assistant on the HDMI design in Intel® Quartus® Prime Standard Edition Software? Description When running Design Assistant on the HDMI design in the Intel® Quartus® Prime Standard Edition Software, you will encounter an error with the following message: Info: Reading SDC File: 'hdmi_tx/hdmi_tx/synthesis/submodules/bitec_hdmi.sdc' Error: ERROR: Quartus Prime Tcl package "::quartus::design" is only available for use in the following executables This is due to get_entity_instances being used within the HDMI .sdc file. This command is not supported in the Intel® Quartus® Prime Standard Edition Software version of the Design Assistant. The command is supported in the Intel® Quartus® Prime Standard Edition Software Fitter and Timequest. Resolution To work around this problem, Intel® Quartus® Prime Pro Edition Software can be used. Custom Fields values: ['novalue'] Troubleshooting FB: 504971; True ['HDMI'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 17.1 ['Arria® V FPGAs and SoCs', 'Arria® 10 FPGAs and SoCs', 'Cyclone® 10 FPGAs', 'Stratix® V FPGAs'] ['novalue'] ['novalue'] ['novalue'] - 2023-01-30