Why are the Datasheet Report and Setup / Hold Time Reports not generated automatically? - Why are the Datasheet Report and Setup / Hold Time Reports not generated automatically? Description The Intel® Quartus® Prime software version 15.1 and later, does not automatically generate the Datasheet report and the Setup / Hold Time reports after a compile. The generation process of those reports was removed from the Intel Quartus default flow to improve the compile time. Resolution To generate these reports as part of Intel® Quartus® Prime compile flow, follow the next steps: Create a new tcl file and name it ' report_datasheet.tcl ' Add the following lines to report_datasheet.tcl create_timing_netlist read_sdc update_timing_netlist # Generate Datasheet Report # ------------------------------------------------- # ------------------------------------------------- report_datasheet -file datasheet_report.rpt -multi_corner # Generate IO Report # ------------------------------------------------- # ------------------------------------------------- qsta_utility::generate_all_io_timing_reports -file io_report.rpt In Assignments > Settings > 'Timing Analyzer', add report_datasheet.tcl in the 'TCL Script File name' field. Make sure that 'Run default timing analysis before running custom script' is checked. After this change, both reports will be generated as part of the compile flow. Custom Fields values: ['novalue'] Troubleshooting FB: 296348; False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 15.1 ['Programmable Logic Devices'] ['Altera® FPGA Programming Software'] ['novalue'] ['novalue'] - 2021-08-25