Specifying -operating_conditions option can cause SDC commands to be ignored silently - Specifying -operating_conditions option can cause SDC commands to be ignored silently
Description In Quartus ® Prime Standard Edition, sepcifying the -operating_conditions option with the set_timing_derate or set_annoted_delay SDC commands causes the commands to be ignored silently for all supported product families except Arria ® 10. Resolution Apply the the set_timing_derate or set_annoted_delay SDC commands to all timing corners by not specifying the -operating_conditions option.