The PowerPlay Power Analyzer reports incorrect power for some Cyclone V and Arria V SoCs - The PowerPlay Power Analyzer reports incorrect power for some Cyclone V and Arria V SoCs Description In the Quartus II software release version 14.0, the PowerPlay Power Analyzer reports incorrect power for some Cyclone V and Arria V SoCs. The total static power reported does not include the hard processor system (HPS) static power for the maximum power characteristic, so the total power is incorrect. This issue affects the following Cyclone V SoCs: 5CSXFC5 5CSXFC6 5CSTFD5 5CSTFD6 This issue affects the following Arria V SoCs: 5ASXFB3 5ASXFB5 5ASTFD3 5ASTFD5 Resolution This issue is fixed in the Quartus II software release version 14.1. For the Quartus II software release version 14.0, you must use the PowerPlay Early Power Estimator (EPE) to determine the correct total power. Custom Fields values: ['novalue'] Troubleshooting novalue True ['novalue'] ['FPGA Dev Tools Quartus II Software'] 14.1 14.0 ['Arria® V FPGAs and SoCs', 'Cyclone® V FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25

external_document