Calibration May Fail Without Issuing CAL_FAIL Signal - Calibration May Fail Without Issuing CAL_FAIL Signal
Description This problem affects DDR2 and DDR3, QDR II, and RLDRAM II products.. For Stratix V devices using the Nios II-based sequencer, calibration may fail without asserting the CAL_FAIL signal, causing calibration to continue indefinitely. Resolution It is safe to assume that calibration has failed after five seconds of no response; in this circumstance, you may abort the calibration operation. This issue will be fixed in a future version of the external memory interface IP
Custom Fields values:
['novalue']
Troubleshooting
novalue
True
['Nios® II Processor']
['FPGA Dev Tools Quartus II Software']
novalue
11.1.2
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document