Has the error type definition of the error message queue been changed in Intel® Stratix® 10 device since Intel® Quartus® Prime Pro version 19.3? - Has the error type definition of the error message queue been changed in Intel® Stratix® 10 device since Intel® Quartus® Prime Pro version 19.3?
Description Yes. Although the Intel® Stratix® 10 SEU Mitigation User Guide (UG-S10SEU | 2020.09.24) Table 3 Error Message Queue Description says Bit 31:29-Error type: 10=multi-bit, it was changed as follows: For Intel® Quartus® Prime Pro version 19.3 or later, Bit 31:29-Error type: 010=multi-bit has been changed to 011=uncorrectable multi-bit For Intel® Quartus® Prime Pro prior to 19.3, Bit 31:29-Error type: 010=multi-bit remains unchanged. This change will be described in a future release of the Intel® Stratix® 10 SEU Mitigation User Guide.
Custom Fields values:
['novalue']
Troubleshooting
1508642605
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
19.3
['Stratix® 10 FPGAs and SoCs', 'Stratix® 10 GX FPGA', 'Stratix® 10 MX FPGA', 'Stratix® 10 TX FPGA']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document