Implementation of ALTGX megafunction in Deterministic Latency mode might generate a warning message in the Quartus II software for Cyclone IV GX - Implementation of ALTGX megafunction in Deterministic Latency mode might generate a warning message in the Quartus II software for Cyclone IV GX Description If you implement an ALTGX megafunction in Deterministic Latency mode, the Quartus II software might generate messages similar to the following:Warning (10541): VHDL Signal Declaration warning at c4gx_test.vhd(62): used implicit default value for signal "pll_reconfig_done" because signal was never assigned a value or an explicit default value. Use of implicit default value may introduce unintended design optimizations.Warning (10036): Verilog HDL or VHDL warning at c4gx_test.vhd(142): object "wire_receive_pcs0_signaldetect" assigned a value but never read Resolution You may safely ignore these messages. Custom Fields values: ['novalue'] Troubleshooting novalue True ['novalue'] ['FPGA Dev Tools Quartus II Software'] 10.0 10.0 ['Cyclone® IV FPGAs'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25