Why do I incorrectly read "X" when simulating memories using altera_syncram in the Synopsys* VCS* simulator? - Why do I incorrectly read "X" when simulating memories using altera_syncram in the Synopsys* VCS* simulator?
Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.3 and earlier, you may observe an incorrect "X" value on the output data in the altera_syncram simulation model block. This problem occurs when you turn on X-prop mode in the Synopsys* VCS* simulator. Resolution To work around this problem, exclude the altera_syncram module from the Synopsys* VCS* simulator X-prop mode.
Custom Fields values:
['novalue']
Troubleshooting
1508806207
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
No plan to fix
21.3
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2023-03-07
external_document