Internal Error: Sub-system: EMIF, File: /quartus/periph/emif/emif_gen6_netlist_modifier.cpp, Line: 1119 Expected only one, but found 2 atoms with SOFT_NIOS_ADDR port connected! - Internal Error: Sub-system: EMIF, File: /quartus/periph/emif/emif_gen6_netlist_modifier.cpp, Line: 1119 Expected only one, but found 2 atoms with SOFT_NIOS_ADDR port connected! Description Due to a problem in the Quartus® Prime Pro edition software you may see this internal error if you connect the cal_debug Avalon® slave interface of more than one EMIF IP in the same IO column. Resolution This configuration is illegal. To avoid this error do not connect more than one cal_debug Avalon slave interface in the same IO column. This configuration is scheduled to generate a helpful error message in a future release of the Quartus Prime software. Custom Fields values: ['novalue'] Troubleshooting novalue False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 15.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25