Critical Warning (11887): The following pin <data pin> was placed in a reserved GND location. This may cause decreased performance for HMC. Altera recommends the pin location to be grounded - Critical Warning (11887): The following pin <data pin> was placed in a reserved GND location. This may cause decreased performance for HMC. Altera recommends the pin location to be grounded Description The following critical warning may appear after the fitter stage when an unused data pin is placed on a reserved hard memory controller (HMC) GND pin. Critical Warning (11887): The following pin <data pin> was placed in a reserved GND location. This may cause decreased performance for HMC. Altera recommends the pin location to be grounded Resolution This critical warning may safely be ignored without losing HMC performance. Custom Fields values: ['novalue'] Troubleshooting 1408189509 False ['DDR3 SDRAM Controller with UniPHY IP'] ['FPGA Dev Tools Quartus II Software'] novalue 13.1 ['Arria® V GT FPGA', 'Arria® V GX FPGA', 'Arria® V GZ FPGA', 'Arria® V ST FPGA', 'Arria® V SX FPGA', 'Cyclone® V E FPGA', 'Cyclone® V GT FPGA', 'Cyclone® V GX FPGA', 'Cyclone® V SE FPGA', 'Cyclone® V SX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2023-03-07