An error occurred while linking the project to the device - An error occurred while linking the project to the device
Description Due to a problem in the Quartus® Prime Pro Edition Software version 19.3, you may see a design link error in the EMIF Toolkit with the following message: "An error occured while linking the project to the device" Resolution Once a programming .sof file is linked through the "Link Project to Device" step in the EMIF Toolkit, and then unlinked through the "Unlink Project from Device" step, the same programming .sof file can't be re-linked through the "Link Project to Device" step again. If this is required, you will need to close the EMIF Toolkit and then re-open it.
Custom Fields values:
['novalue']
Troubleshooting
1409892853
True
['External Memory Interfaces Arria® 10 FPGA IP', 'External Memory Interfaces Cyclone® 10 FPGA IP', 'External Memory Interfaces Stratix® 10 FPGA IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
No plan to fix
19.3
['Arria® 10 FPGAs and SoCs', 'Cyclone® 10 FPGAs', 'Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-11-21
external_document