Why does nSTATUS assert and stay low after a configuration failure in the Intel® Stratix® 10 devices when using configuration files generated in the Intel® Quartus® Prime Pro Edition Software v18.0? - Why does nSTATUS assert and stay low after a configuration failure in the Intel® Stratix® 10 devices when using configuration files generated in the Intel® Quartus® Prime Pro Edition Software v18.0?
Description When configuring Intel® Stratix® 10 devices with a configuration file generated in the Intel® Quartus® Prime Pro Edition Software v18.0, you might see nSTATUS assert and remain low after a configuration error is detected. This behavior may be seen in all supported configuration modes other than JTAG configuration. Resolution If nSTATUS asserts low due to a configuration failure, drive nCONFIG low after 1.5 ms and then back high to initiate reconfiguration. The nSTATUS signal will deassert to a high state to then allow reconfiguration to proceed. This problem is fixed starting from the Intel® Quartus® Prime Pro Edition Software v18.0.1.
Custom Fields values:
['novalue']
Troubleshooting
FB: 490320;
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
18.0.1
18.0
['Stratix® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2023-01-09
external_document