Why does External Memory Interface (EMIF) calibration fail when you recalibrate the EMIF interface on Agilex™ 7 FPGA and Agilex™ 5 FPGA devices without reconfiguring the device? - Why does External Memory Interface (EMIF) calibration fail when you recalibrate the EMIF interface on Agilex™ 7 FPGA and Agilex™ 5 FPGA devices without reconfiguring the device?
Description Due to an issue in the Quartus® Prime Pro versions 24.1 and earlier, you may encounter EMIF calibration failure if you recalibrate the interface using the EMIF Debug Toolkit or using the mailbox command on Agilex™ 7 FPGA M-Series and Agilex™ 5 FPGA E-Series devices. Resolution To work around this issue, reconfigure the device to recalibrate the EMIF interface.
Custom Fields values:
['novalue']
Troubleshooting
15015713022
False
['External Memory Interfaces (EMIF) IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
No plan to fix
24.1
['Agilex™ 5 FPGA E-Series', 'Agilex™ 7 FPGA M-Series']
['novalue']
['novalue']
['novalue'] - 2024-05-30
external_document