Why do I see configuration failure in my Intel® Arria® 10 or Intel® Cyclone® GX device when using Chip ID IP core? - Why do I see configuration failure in my Intel® Arria® 10 or Intel® Cyclone® GX device when using Chip ID IP core?
Description Due to a problem with Intel Quartus® software, you may have a configuration failure if your design has Chip ID IP core. When this occurs you may see the following behavior: JTAG does not respond unless you power cycle the device nStatus signal stays low and does not return to a high value Resolution To work around this problem, hold Chip ID IP core in reset when using JTAG and doing device reconfiguration.
Custom Fields values:
['novalue']
Troubleshooting
FB: 545041;
False
['Chip ID Stratix® 10 FPGA IP', 'JTAG UART IP', 'Partial Reconfiguration Controller Arria® 10 Cyclone® 10 FPGA IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
18.0.1
17.1.1
['Arria® 10 FPGAs and SoCs', 'Cyclone® 10 FPGAs']
['novalue']
['Configuration Devices']
['novalue'] - 2021-08-25
external_document