Why do I encounter Read response data loss in simulation when you enable Fabric NoC with Agilex™ 7 FPGA HBM2E IP in Quartus® Prime Pro Edition Software version 22.4? - Why do I encounter Read response data loss in simulation when you enable Fabric NoC with Agilex™ 7 FPGA HBM2E IP in Quartus® Prime Pro Edition Software version 22.4? Description This issue mainly happens in simulation. You might see data loss in the read response when you enable the Agilex™ 7 FPGA HBM2E IP with Fabric NoC option and back-pressure the read response data path for more than 500 cycles. Resolution This issue has been fixed in Quartus® Prime Pro Edition Software version 24.3 and onwards. Custom Fields values: ['novalue'] Troubleshooting 16018488105 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 24.3 22.4 ['Agilex™ 7 FPGA M-Series'] ['novalue'] ['novalue'] ['novalue'] - 2025-09-04