Error (16058): PLLs that use the x1 clock network and drive the same HSSI channel must be placed in the same transceiver bank - Error (16058): PLLs that use the x1 clock network and drive the same HSSI channel must be placed in the same transceiver bank Description Due to a problem with Intel® Quartus® Prime Standard Edition Software version 18.1 or later, you might see this error when using Arria® V devices, even though your TX PLL is located in the same transceiver bank as the transceiver channels. Resolution To workaround this problem you can use Intel® Quartus® Prime Standard Edition Software version 18.0 or earlier. This problem is fixed in the Intel® Quartus® Prime Standard Edition Software versions 23.1. Custom Fields values: ['novalue'] Troubleshooting 16021509935 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Standard'] novalue 18.1 ['Arria® V FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-10-19