Simulation Result Incorrect Using MCV Interpolation Filters - Simulation Result Incorrect Using MCV Interpolation Filters Description Some multicycle variable interpolation filters with high interpolation factors may generate incorrect output. This issue affects MCV interpolation filters with high interpolation factors and forced non-symmetric implementation where the pipelining level is set to greater than 1 for higher f MAX . The produced output does not match the expected output. Resolution Change the pipelining level to 1. This change may result in lower f MAX but the filter output will match the expected output. Custom Fields values: ['novalue'] Troubleshooting novalue True ['Filters'] ['FPGA Dev Tools Quartus II Software'] novalue 10.0 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25