Why does the generated Stratix® 10 100G Ethernet soft IP with RS-FEC example design fail to complete simulation? - Why does the generated Stratix® 10 100G Ethernet soft IP with RS-FEC example design fail to complete simulation? Description Due to a problem in the simulation testbench of the example design generated by the Quartus® Prime Pro Software version 17.1.1, the simulation fails to complete. You will see the simulation hang at packet 10 as shown below. *************************************************** ************** Recieve Ready ****************** *************************************************** Transmitting test data ** Sending Packet 1... ** Sending Packet 2... ** Sending Packet 3... ** Sending Packet 4... ** Sending Packet 5... ** Sending Packet 6... ** Sending Packet 7... ** Sending Packet 8... ** Sending Packet 9... ** Sending Packet 10... Resolution To work around this problem, replace the original generated testbench <your example project>/example_testbench/basic_avl_tb_top.v with this new testbench . This problem is scheduled to be fixed in a future version of the Quartus® Prime Pro Software. Custom Fields values: ['novalue'] Troubleshooting FB: 535256; False ['Low Latency 100G Ethernet IP for Arria® 10 and Stratix® V'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 18.0 17.1.1 ['Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2024-11-21