Error: Fail to read Silicon ID - Error: Fail to read Silicon ID Description Due to a problem in the Intel® Quartus® Prime Software version 16.0 and earlier, quartus_hps might fail to re-program quad serial peripheral interface (SPI) devices on Cyclone® V SoC, Arria® V SoC, or Intel® Arria® 10 FPGA systems. The following error messages might be seen: Error: Fail to match data at flash address <address> with file address <address>. Error: Fail to read Silicon ID Resolution A patch is available to fix this problem for the Intel® Quartus® Prime Software version 16.0. Follow these steps: Download and install patch 0.01 from the following links: Intel Quartus Prime Software version 16.0 Patch 0.01 for Windows (.exe) Intel Quartus Prime Software version 16.0 Patch 0.01 for Linux (.run) Readme for the Intel Quartus Prime Software version 16.0 Patch 0.01 for (.txt) Note: This patch cannot be applied to SoC Embedded Design Suite (EDS) or the Intel Quartus Prime Software Standalone Programmer Run quartus_hps to program the device adding the --boot=18 option to the command line. The --boot=18 option causes a cold reset to be applied to the SoC prior to quad SPI programming. For example: quartus_hps -c 1 -o PV --boot=18 -a 0x0 <filename>.img This patch is scheduled to be included in a future release of the Intel Quartus Prime Software. Custom Fields values: ['novalue'] Troubleshooting FB: 336330; False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Standard'] 16.1 15.1 ['Arria® V ST FPGA', 'Arria® V SX FPGA', 'Cyclone® V SE FPGA', 'Cyclone® V ST FPGA', 'Cyclone® V SX FPGA', 'Arria® 10 SX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2023-01-27