Fault Injection Not Supported in Agilex™ 7 FPGA M-Series Without R0 Suffix in Quartus® Prime Pro Edition Design Software version 24.3.1 - Fault Injection Not Supported in Agilex™ 7 FPGA M-Series Without R0 Suffix in Quartus® Prime Pro Edition Design Software version 24.3.1
Description Due to a problem in Quartus® Prime Pro Edition Software version 24.3.1, the fault injection feature is not supported in Agilex™ 7 FPGA M-Series devices with OPNs that do not include the R0 suffix. You can enable the fault injection feature in Quartus® Prime Software but fail to run the Fault Injection Debugger on hardware. There is no impact on the SEU feature; you can still enable it for error detection and correction. Resolution This problem is planned to be fixed in a future release of Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Troubleshooting
16026071946
False
['Fault Injection IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
25.1
24.3.1
['Agilex™ 7 FPGA M-Series']
['novalue']
['novalue']
['novalue'] - 2024-12-05
external_document
- Resource Type
- Support Resources > Knowledge Articles
- Source Name
- khoros