Altera PLL v12.0: Entering output phase shift in degree units causes incorrect simulation - Altera PLL v12.0: Entering output phase shift in degree units causes incorrect simulation
Description By default, phase shifts in the Altera PLL v12.0 MegaWizard Plug-In Manager are specified in degree units. However, if you specify an output phase shift in degree units, the phase shift is not simulated correctly. Resolution To simulate the phase shift correctly, either specify the output phase shift in picoseconds or, in your .vo or .vho file include ps in your instantiation. For example, in the .vo or .vho file change xxxxx.phase_shift0 = 5000 to xxxxx.phase_shift0 = “5000 ps”