What is the SDM (Secure Device Manager) fuse requirement for Current IFUSEWR_SDM when using the Agilex™ 7 FPGAs and SoC FPGAs F-Series, and I-Series? - What is the SDM (Secure Device Manager) fuse requirement for Current IFUSEWR_SDM when using the Agilex™ 7 FPGAs and SoC FPGAs F-Series, and I-Series?
Description There is no requirement for the SDM fuse Current I FUSEWR_SDM in the Recommended Operating Conditions of Agilex™ 7 FPGAs and SoCs Device Data Sheet: F-Series and I-Series . Resolution The requirement is the same as Recommended Operating Conditions of Agilex™ 7 FPGAs and SoCs Device Data Sheet: M-Series . Symbol Description Condition Minimum Typical Maximum Unit I FUSEWR_SDM SDM fuse Current Static — — 50 mA Dynamic average AC during sensing and programming — 0.6 — mA