Why do I see configuration failure in Arria 10 multi-device Active Serial configuration scheme? - Why do I see configuration failure in Arria 10 multi-device Active Serial configuration scheme?
Description In Arria® 10 Active Serial (AS), multi-device configuration will fail if the configuration bitstream of the slave device span across the EPCQ-L die boundary. EPCQ-L1024 has 4x256Mb die EPCQ-L512 has 2x256Mb die After the master device is configured, it will continue to read the bitstream from EPCQ-L flash to configure the slave device. The Arria® 10 device control block will issue additional read command when crossing the EPCQ-L die boundary. This additional command causes unexpected data being read by the slave device during configuration. This issue affect all Arria® 10 devices. Resolution Compress the bitstream and make sure both master and slave devices configuration bitstreams are stored within the 256Mb die boundary of EPCQ-L device.
Custom Fields values:
['novalue']
Troubleshooting
FB: 498389;
False
['novalue']
['novalue']
novalue
novalue
['Arria® 10 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2022-12-22
external_document