Why does my Signal Tap instance fail to trigger correctly after the first successful power-up triggered acquisition? - Why does my Signal Tap instance fail to trigger correctly after the first successful power-up triggered acquisition? Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software version 21.3, you may see your Signal Tap instance uses the initial power up trigger instead of the trigger condition you have set. Resolution To work around this problem, create a new Signal Tap instance without the power-up trigger enabled. This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 14015124740 False ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 22.3 21.3 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2023-01-23