Why does the Even-Odd-Jitter(EOJ) of the FHT transmitter fail compliance specification with the ethernet line rate above 25.78125 Gbps? - Why does the Even-Odd-Jitter(EOJ) of the FHT transmitter fail compliance specification with the ethernet line rate above 25.78125 Gbps?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 23.3, you may see the EOJ of the FHT transmitter fail compliance specification with the Ethernet line rate above 25.78125 Gbps. The below FHT variants are failing. FHT NRZ 29 Gbps FHT PAM4 116 Gbps FHT NRZ 28 Gbps FHT PAM4 106.25 Gbps Resolution This problem is fixed beginning with the Quartus® Prime Pro Edition software version 24.3.
Custom Fields values:
['novalue']
Errata
16021955346, 16021007554
False
['F-Tile PMA/FEC Direct PHY IP']
['FPGA Dev Tools Quartus® Prime Software Pro']
24.3
23.3
['Agilex™ 7 FPGAs and SoCs']
['novalue']
['novalue']
['novalue'] - 2024-04-07
external_document