External Memory Interfaces Targeting Some Stratix V Devices Do Not Function Correctly in Hardware - External Memory Interfaces Targeting Some Stratix V Devices Do Not Function Correctly in Hardware Description This problem affects DDR2, DDR3, QDR II, RLDRAM II and RLDRAM 3 products. External memory interfaces using pins in banks 7E or 8E of the following Stratix V devices will not function correctly in hardware: 5SGXBB 5SGXB9 5SGXAB 5SGXA9 5SEEB 5SEE9 The cause of this problem is that connections from levelling delay chains to I/O banks are swapped for banks 7E and 8E in the software model for the affected devices. Resolution The workaround for this issue is to install the latest patch for your version. This issue will be fixed in a future version. Custom Fields values: ['novalue'] Troubleshooting novalue True ['novalue'] ['FPGA Dev Tools Quartus II Software'] novalue 12.0.2 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25