RapidIO II IP Core Transmits link-response Control Symbols With Incorrect port_status Value - RapidIO II IP Core Transmits link-response Control Symbols With Incorrect port_status Value Description When the RapidIO II IP core transmits a link-response control symbol, it does not provide a correct value in the port_status field. Resolution This issue has no workaround. The IP core’s RapidIO link partner should not rely on the value in the port_status field of link-response control symbols it receives from the IP core. This issue will be fixed in a future version of the RapidIO II MegaCore function. Custom Fields values: ['novalue'] Troubleshooting novalue True ['novalue'] ['FPGA Dev Tools Quartus II Software'] novalue 12.1 ['Programmable Logic Devices'] ['novalue'] ['novalue'] ['novalue'] - 2021-08-25