CPRI IP Core Variations That Target a Cyclone V GX Device Do Not Achieve Timing Closure - CPRI IP Core Variations That Target a Cyclone V GX Device Do Not Achieve Timing Closure
Description CPRI IP core variations that target a Cyclone V GX device fail to achieve timing closure with the default Quartus II Fitter settings. Specifically, they experience hold time violations on the PCS-PLD path. Resolution To achieve better timing closure results, perform one of the following actions: Add set_min_delay assignments to overconstrain timing. Try different Quartus II Fitter seeds. This issue will be fixed in a future version of the CPRI MegaCore function.
Custom Fields values:
['novalue']
Troubleshooting
novalue
True
['novalue']
['FPGA Dev Tools Quartus II Software']
novalue
12.1.1
['Programmable Logic Devices']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document