Why do I see Board Selection Out of Range, when using the Stratix 10 Interlaken IP Core? - Why do I see Board Selection Out of Range, when using the Stratix 10 Interlaken IP Core?
Description When using the Intel® Stratix® 10 Interlaken IP Core (2nd Generation), you will see the error " Select Board (BOARD_SELECTION) 1 is out of range: No Development Kit ", if the project device part is different to that on the dev it, and " Select Board " parameter is set to " Stratix 10 GX Signal Integrity Development Kit ". The device fitted to the Stratix 10 GX Signal Integrity Development kit is the 1SG280HU2F50E2VGS1. Resolution To work around this problem, ensure your project device is set to that on the Stratix 10 GX Signal Integrity Kit(1SG280HU2F50E2VGS1), or set " Select Board " to " No Development Kit ". This problem is scheduled to be fixed in a future release of the Intel Quartus® Prime Pro software.
Custom Fields values:
['novalue']
Troubleshooting
FB: 495144;
True
['Interlaken', 'Interlaken - 100G for 28nm and 20nm devices (PRIMARY) IP-ILKN/100G', 'Interlaken - 50G for 28nm and 20nm devices (PRIMARY) IP-ILKN/50G']
['FPGA Dev Tools Quartus® Prime Software Pro']
novalue
17.1
['Stratix® 10 FPGAs and SoCs', 'Stratix® 10 GX FPGA']
['novalue']
['novalue']
['novalue'] - 2021-08-25
external_document