Why does Quartus® Prime Pro Edition Power and Thermal Calculator (PTC) Thermal Page display sensors that do not match those specified in the Agilex™ 7 FPGA Power Management User Guide? - Why does Quartus® Prime Pro Edition Power and Thermal Calculator (PTC) Thermal Page display sensors that do not match those specified in the Agilex™ 7 FPGA Power Management User Guide?
Description The Agilex ™ 7 FPGA Power Management User Guide lists available temperature sensor locations and TSDs for different Agilex™ 7 FPGA device densities. However, due to a problem in Quartus® Prime PTC tool version 23.1, the thermal page displays unavailable sensors that do not match the ones listed as available. This happens for devices whose specifications are currently in the advanced or preliminary stage. Resolution You should consider only the sensors that match the ones displayed as available in the Agilex™ 7 FPGA Power Management User Guide.
Custom Fields values:
['novalue']
Troubleshooting
22018128518
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
No plan to fix
23.1
['Agilex™ 7 FPGAs and SoCs']
['Altera® FPGA Power Thermal Calculator']
['novalue']
['novalue'] - 2025-06-02
external_document
- Resource Type
- Support Resources > Knowledge Articles
- Source Name
- khoros