Error(23098): One or more blocks are configured incorrectly and will not have the desired functionality. --BCM instance name: pio_1_2 - Error(23098): One or more blocks are configured incorrectly and will not have the desired functionality. --BCM instance name: pio_1_2 Description Due to a problem in the Quartus® Prime Pro Edition Software version 26.1 and earlier, you might see the error above when using the I/O PLL Parameterizable Macro (ipm_iopll). The error only occurs when using non-integer values for the VCO Clocks and Output Clocks in the I/O PLL Parameterizable Macro. Resolution To work around this problem, use non‑integer values for the VCO Clocks and Output Clocks in the IOPLL IP. This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting QS-23747 novalue ['novalue'] ['FPGA Dev Tools Quartus® Prime Software Pro'] novalue 26.1 ['Agilex™ 3 FPGAs and SoCs', 'Agilex™ 5 FPGAs and SoCs', 'Agilex™ 7 FPGAs and SoCs', 'Agilex™ 9 FPGAs and SoCs', 'Arria® 10 FPGAs and SoCs', 'Cyclone® 10 GX FPGA'] ['novalue'] ['novalue'] ['novalue'] - 2026-05-20