Description By clicking the IP Toolbench Generate button, you start generating a POS-PHY Level 4 MegaCore function variation. If, during generation, you click the Cancel button (Generation window) and click the IP Toolbench Generate button again to restart the generation, IP Toolbench fails and produces the following error message: MegaCore Function Generation Error Can’t bless non-reference value at (eval 1) line 73. This issue affects all variations of the MegaCore function.IP Toolbench does not generate any files. Resolution To cancel a generation and avoid this error, follow these steps: Click the Cancel button in the Generation window. Close IP Toolbench by clicking the × in the upper right corner. Relaunch IP Toolbench from the MegaWizard Plug-In Manager (Tools menu). Refer to the Getting Started chapter of the POS-PHY Level 4 MegaCore Function User Guide for instructions on using IP Toolbench.