Are the internal clamping diodes on Intel® Arria® V FPGA GPIO pins active at all times? - Are the internal clamping diodes on Intel® Arria® V FPGA GPIO pins active at all times?
Description When the device is not powered on or when the device is not configured, are the internal clamping diodes on Intel® Arria® V FPGA GPIO pins active? Resolution Based on the Arria® V Device Handbook: Volume 1: Device Interfaces and Integration , the on-chip Clamping Diode feature is enabled and disabled through Intel® Quartus® Prime Software and limited to certain supported I/O standards. For the unconfigured case, users cannot use the on-chip Clamping Diode feature. In other words, the on-chip Clamping Diodes are not applied to the GPIO pins when the device is not fully configured. Related Articles Are the internal clamping diodes on Intel® MAX® 10 or Intel® Cyclone® 10 LP devices active at all times?