Why do I see incorrect signal values at the Control Shadow Interface of the GTS AXI Streaming FPGA IP for PCI Express*? - Why do I see incorrect signal values at the Control Shadow Interface of the GTS AXI Streaming FPGA IP for PCI Express*?
Description Due to a problem in the Quartus® Prime Pro Edition Software version 24.1, you may see the signal values for TPH Enable, ATS Enable, VF Enable, and Page Request Enable of the Control Shadow Interface do not match the register fields of the associated function, leading to incorrectness. Resolution This problem is scheduled to be fixed in a future release of the Quartus® Prime Pro Edition Software.
Custom Fields values:
['novalue']
Errata
15015588232, 16023878212
False
['novalue']
['FPGA Dev Tools Quartus® Prime Software Pro']
24.2
24.1
['Agilex™ 5 FPGA E-Series']
['novalue']
['novalue']
['novalue'] - 2024-12-01
external_document