Why is the timestamp accuracy of Intel® Stratix® 10 1G/2.5G/5G/10G Multi-Rate Ethernet PHY Intel® FPGA IP with variant MGBASE-T PHY lower than the expected value? - Why is the timestamp accuracy of Intel® Stratix® 10 1G/2.5G/5G/10G Multi-Rate Ethernet PHY Intel® FPGA IP with variant MGBASE-T PHY lower than the expected value? Description Due to a problem in the Intel® Quartus® Prime Pro Edition Software Version 22.3, Intel® Stratix® 10 design with 1G/2.5G/5G/10G Multi-rate Ethernet PHY Intel® FPGA IP with variant MGBASE-T has a higher than expected Precision Time Protocol (PTP) timestamp accuracy value. Accuracy failure is observed when the speed selected is 2.5G and lower. Resolution Currently there is no workaround. This problem is scheduled to be fixed in a future release of the Intel® Quartus® Prime Pro Edition Software. Custom Fields values: ['novalue'] Troubleshooting 15012130624 False ['1G 2.5G 5G 10G Multi-rate Ethernet PHY IP'] ['FPGA Dev Tools Quartus® Prime Software Pro'] 23.3 22.3 ['Stratix® 10 FPGAs and SoCs'] ['novalue'] ['novalue'] ['novalue'] - 2023-11-27